The aluminum core PCB(MCPCB) is a metal-based copper-clad laminate with good heat dissipation. In general, a single-sided MCPCB consists of three-layer structure, which is a circuit layer (copper foil), an insulation layer, and a metal substrate. For high-end use is also designed as a double-sided board, the structure of the circuit layer,insulation layer, aluminum, insulation, circuit layer. A very small number of applications are multilayer boards, which can be made of ordinary multilayer boards with insulating layers and aluminum substrates.
MCPCB construction
1. Circuit Layer
The circuit layer (usually electrolytic copper foil) is etched to form a printed circuit for the assembly and connection of the device. Compared with traditional FR-4, with the same thickness, the same line width, aluminum core PCB(MCPCB) can carry higher current.
2. Dielectric Layer
Dielectric layer is the core technology of aluminum core PCB(MCPCB), which mainly functions as bonding, insulation and heat conduction. MCPCB dielectric is the largest thermal barrier in the power module structure. The better of thermal conductivity of dielectric layer, the more conducive to the dissipation of heat generated during the operation of the device, the more conducive to reducing the operating temperature of the device, so as to achieve the purpose of increasing the power load of the module, reducing the size, extending the life, increasing the power output, etc. .
3. Metal Substrate Layer
Which kind of metal is used for the insulating metal substrate depends on the comprehensive consideration of the thermal expansion coefficient, thermal conductivity, strength, hardness, weight, surface condition and cost of the metal substrate. Under normal circumstances, considering the conditions of cost and technical performance, aluminum sheet is an ideal choice. Available aluminum plates are 6061, 5052, 1060, etc.If there are higher requirements for thermal conductivity, mechanical properties, electrical properties and other special properties, copper plates, stainless steel plates, iron plates and silicon steel plates can also be used.
The thermal conductivity of metal core PCB(MCPCB):
Item | Test Condition | Units | KS-101 | KS-110 | KS-111 |
Thermal Conductibility | A | W/m.k | 1.0-1.8 | 1.0-2.0 | 1.8-3.0 |
Peel Strength | A(After thermal stress | N/mm | 1.3 | 1.8 | 1.5 |
Thermal Stress | 288℃ | S | 30S | 90S | 120S |
Surface Resistance | C-96/35/90 E-24/125 | MΩ | 107 | 107 | 107 |
Volume Resistivity | C-96/35/90 E-24/125 | MΩ | 105 | 105 | 105 |
Electrical Strengthen | A | KV/mm | 30 | 30 | 30 |
Flammability | UL94 | – | V-0 | V-0 | V-0 |
Tg | A | ℃ | 130 | 100 | 100 |
Moisture Absorption | D-24/23 | % | 0.1 | 0.03 | 0.03 |
CTI | IEC60112 | V | 250 | 600 | 600 |
Item | Test Condition | Units | KS-112 | KS-113 | KS-114 |
Thermal Conductibility | A | W/m.k | 2.5-5.0 | 1.5-2.0 | 1.5-2.0 |
Peel Strength | A(After thermal stress | N/mm | 1.3 | 1.3 | 1.3 |
Thermal Stress | 288℃ | S | 120S | 120S | 600S |
Surface Resistance | C-96/35/90 E-24/125 | MΩ | 107 | 107 | 107 |
Volume Resistivity | C-96/35/90 E-24/125 | MΩ | 105 | 105 | 105 |
Electrical Strengthen | A | KV/mm | 30 | 30 | 30 |
Flammability | UL94 | – | V-0 | V-0 | V-0 |
Tg | A | ℃ | 100 | 170 | 100 |
Moisture Absorption | D-24/23 | % | 0.03 | 0.03 | 0.03 |
CTI | IEC60112 | V | 600 | 600 | 600 |